Q:What is the situation with inaccurate heart rate data?
A:[Cause/Principle]
Watch heart rate is measured through a wrist optical sensor. Wearing too loose, improper position, wrist shaking, sweating, and exercise type all affect readings. The heart rate detection hardware capability of this model also has certain limitations; stability and follow-up speed may vary in some users or exercise scenarios.
[Normal Range]
Occasional small fluctuations in resting state, or short-term deviations during running and strength training may occur. Heart rate data is for daily health and sports reference, not for medical diagnosis.
[Standard Test/Troubleshooting]
1) Wear the watch about 1-2 fingers above the wrist bone and tighten appropriately; 2) Dry the sensor and skin; 3) Sit still and rest for 5 minutes; 4) Keep arm still, measure 2-3 times continuously; 5) If comparing with other devices, test at the same time and in the same state as much as possible.
[Abnormal Determination]
If obvious jumps, long-term no reading, or obvious inconsistency with actual state still occur continuously after correct wearing and static testing, record test video, watch model, and software version, and forward to after-sales for further investigation.